Tripp Lite Metered ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.
|
General
|
|
|
Form Factor
|
Rack-mountable
|
|
Actual Weight
|
10.30 lb(s)
|
|
Compatibility Notes
|
Key Features
200-240V 16A Automatic Transfer Switch (ATS) / Metered PDU (Power Distribution unit) Provides a redundant power option for critical networking equipment with a single input power cord 2-digit display reports output power consumption in amps 1U horizontal rackmount form factor; 14.8 in. / 37.6 cm depth (10) outlets (8 C13, 2 C19) Set of two C20 inlets support connection to separate PRIMARY and SECONDARY power sources ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series) Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source Super-fast switchover between primary and secondary power sources occurs in 2-5 milliseconds Built-in card slot supports optional SNMPWEBCARD for permanent upgrade to a switched & monitored PDU system Outlets are factory programmed for sequential turn-on at 250 milliscond intervals when the PDU is first energized to prevent inrush-related equipment interaction on startup Front panel LEDs confirm power availability on both input lines
LEDS ALARMS & SWITCHES
Switches: Toggle switch near digital display enables the setting of "HI" for 220, 230 or 240V nominal applications or "LO" for 200 or 208V applications Front panel: (8) front panel LEDs display power on - off status for each C13 outlet, plus (2) LEDs for power status on Primary and Secondary input connection. Digital current meter display shows the amount of power consumption in amps for entire PDU output.
Other Features
Appearance: 1U rackmount steel chassis, black Certifications: Tested to UL 60950 (USA, Canada), CE (Europe), Class A (Emissions), NOM (Mexico), RoHS Complaint
|
|
Contents
|
Unit, documentation
|
|
Physical Dimensions
|
1.7"h x 17.3"w x 14.8"d
|
|
Ports/Connectors
|
Outlet quantity / type: (8) IEC-C13, (2) IEC-C19 Customized load management receptacles: Adding SNMPWEBCARD accessory (available separately) offers upgrade path to switched PDU (only C13 outlets are switchable upon upgrade); SNMPWEBCARD also can be inserted temporarily as a configuration tool to custom program power-on and power-off C13 outlet sequences with user-specified time delays in response to loss and restoration of primary input. PDU input: (2) IEC-320 C20
|
|
Power Notes
|
OUTPUT
Frequency compatibility: 50/60Hz Output nominal voltage: 200V, 208V, 220V, 230V, 240V
INPUT
PDU Input Voltage: 200V, 208V, 230V, 240V Maximum Input current: 20A Voltage compatibility: 200-240VAC Phase: Single-Phase
|
|