- Provides 1600watt(s), 2200VA, 120V power / Surge Suppression is Standard
- Connector(s): Power NEMA 5-20 (F), Power NEMA 5-15 (F), Power NEMA 5-20 (M) / 8 Outlets
- 6 minute(s) Battery Runtime at Full Load / Attributes include Automatic voltage regulation (AVR) Line interactive
Tripp Lite SmartPro Line Interactive UPS with enhanced LCD interface offers network-grade power protection for critical server, network and telecommunications equipment. Line Interactive Uninterruptible Power Supply (UPS) with built-in Auto-Voltage Regulation (AVR) actively corrects brownouts and overvoltages back to usable levels while maintaining a full battery charge in case of power failure. Tripp Lite's unique configuration excels in exceptionally poor-power environments with two separate levels of voltage boost to correct both slight undervoltages and severe brownout conditions. Interactive LCD/LED interface reports UPS operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options. Super-fast switchover from line to battery power occurs within milliseconds to maintain operation of connected equipment without interruption or reboot. 96% line-mode efficiency offers reduced heat emissions and operating costs. Network management interfaces support communications via USB, RS-232 and optional SNMPWEBCARD network interface. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Network communications ports enable detailed monitoring of equipment load levels, self-test data and utility power conditions. Includes PowerAlert monitoring software and complete cabling. Switched output load banks enable scheduled and real-time remote reboot and load shedding of select outlets. Emergency Power Off (EPO) interface. LED/LCD display panel easily rotates for viewing in rackmount or tower configurations. Audible alarm with push-button momentary alarm-cancel and silent-mode configuration options. Programmable self-test. Field-replaceable, hot-swappable battery modules.
|
Connectivity
|
|
|
Communication Interface
|
Serial (RS-232)
|
|
# Ports
|
8
|
|
Communication Interface
|
USB
|
|
Connector
|
Power NEMA 5-20 (F)
|
|
Connector
|
Power NEMA 5-15 (F)
|
|
Connector
|
Power NEMA 5-20 (M)
|
|
General
|
|
|
Form Factor
|
Tower
|
|
Form Factor
|
2U Rackmount
|
|
Attributes
|
Automatic voltage regulation (AVR)
|
|
Attributes
|
Line interactive
|
|
Power
|
|
|
Battery Run Time (max)
|
6 minute(s)
|
|
Power Provided
|
120 V
|
|
Power Provided
|
1600 watt(s)
|
|
Power Provided
|
2200 VA
|
|
Surge Suppression
|
Standard
|
|
Actual Weight
|
57.60 lb(s)
|
|
Compatibility Notes
|
Key Features
Tripp Lite SMART2200RMXL2U line interactive 2U rack/tower UPS with 2200VA / 2.2kVA / 1920W capacity and extended runtime options Line interactive UPS with Automatic Voltage Regulation (AVR) corrects brownouts and overvoltages from 83 to 145V NEMA 5-20P input plug; 4 NEMA 5-15/20R and 4 5-15R output receptacles, Two independently switched output load banks Maintains uninterrupted operation of connected networking equipment during blackouts, surges, brownouts and overvoltages High 96% efficiency rating in line-power mode offers reduced power consumption and BTU emisssions Internal batteries offer 12 minutes at 50% load (960W) and 4.5 minutes at 100% load (1920W) Extended runtime is available with optional BP48V24-2U (limit 1) OR BP48V60RT3U (no limit), Output is reduced to 1600 watts maximum with external battery packs External battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual) Hot-swappable, user-replaceable internal batteries and external battery packs can be replaced with no disruption to connected equipment Front panel LCD monitoring screen with MODE and ENTER buttons reports operating mode with 5-bar battery charge graphic, plus 7 selectable screens of detailed UPS and site power information LCD interface also supports a number of advanced user setup and operating preferences Ships with 4-post rackmount installation hardware; Optional 2POSTRMKITWM enables 2-post rackmount/wallmount installation; Optional 2-9USTAND enables tower placement Built-in USB, RS-232 and optional SNMPWEBCARD accessory monitoring options HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X Included PowerAlert UPS monitoring software; Built-in Emergency Power Off (EPO) interface with cable
|
|
Contents
|
UPS, PowerAlert software CD, USB, serial, EPO cabling, documentation
Instruction manual
|
|
Physical Dimensions
|
3.4"h x 17.3"w x 19.5"d
|
|
Ports/Connectors
|
(4) NEMA 5-15R outlets (4) NEMA 5-15/20R outlets (1) NEMA 5-20P with 10 ft., 12 gauge, black power cord (includes user installable NEMA 5-15P replacement plug) (2) USB management ports (2) DB-9 management ports (1) EPO RJ-11 port
|
|
Power Notes
|
Output:
Output volt-amp capacity: 2200VA Output power capacity: 1600W Output nominal voltage: 120VAC Overload protection: Resettable circuit breaker
Output voltage regulation:
Line mode: Sine wave line voltage 120VAC (-18% / +8%) Battery mode: Sine wave output 120VAC +/-5%
Output frequency regulation:
Line mode: passes line frequency of 60Hz +/-10% Battery mode: inverter output regulated to 60Hz +/-0.5Hz
Input:
Maximum input current: 16A Recommended electrical service: 20A 120VAC
Battery: Full load runtime (minutes) 4.5 min. (1920w) Half load runtime (minutes) 12 min. (960w) Expandable battery runtime Extended runtime supported via optional external battery packs External battery pack compatibility BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible) DC system voltage (VDC) 48 Battery recharge rate (included batteries) Less than 4.5 hours from 10% to 90% Replacement battery cartridge (internal UPS battery replacement) RBC94-2U Battery Access Front panel battery access door Battery replacement description Hot-swappable, user replaceable batteries
Voltage regulation:
Overvoltage correction: input voltages between 128 and 147VAC are reduced by 12% Direct pass through: input voltages between 105 and 127VAC are passed on to connected equipment unchanged Brownout correction: input voltages between 95 and 104VAC are boosted by 12% Severe brownout correction: input voltages between 79 and 94VAC are boosted by 24%
|
|
Returns Policy
|
This product is subject to our return policy. Please see our complete return policy for details.
|
|
Warranty - Labor
|
2 Years
|
|
Warranty - Parts
|
2 Years
|
|
Warranty Details
|
2-year warranty, 3 year with registration. Note: registration is required for 3-year warranty. Connected Equipment Insurance (U.S., Canada & Puerto Rico) $250, 000 Ultimate Lifetime Insurance
|
http://www.macconnection.com/IPA/Shop/Product/Detail.htm?sku=415098#BVSecondaryCustomerRatings