- Provides 3000VA, 3600VA power / Surge Suppression is Standard
- Connector(s): Power NEMA 5-20 (F) Power NEMA L5-30 (F), Power NEMA L5-30 (M), Hardwired / 9 Outlets
- 7.5 minute(s) Battery Runtime at Full Load / Attributes include Line interactive
The Tripp Lite SmartPro Compact Rackmount Uninterruptible Power Supply (UPS) gives you line-interactive voltage regulation, network grade surge suppression and long lasting battery support for critical network hardware during blackouts and extended power failures. Special reduced-depth housing, larger internal batteries, higher rated wattage and an included 2-post rackmount installation kit makes this system ideal for network and telecom wiring closets and other limited-space installations. Runtime is expandable with optional BP48V48RT4U and BP48V24-2U reduced-depth external battery packs.
The SMART3000CRMXL 4U rackmount 3000VA UPS offers battery-derived sine wave AC output during power failures and extreme voltage variations. This unit supports 3000VA/2880 watts when the included L5-30P input plug provides the input power. It will support up to 3300VA/3300 watts when hardwired to a 120V 30A input source.
Line-interactive, Automatic Voltage Regulation (AVR) provides two levels of voltage boost during brownouts and one level of voltage cut during overvoltage conditions to maintain a regulated 120V nominal output over an input range of 83-145V.
Remote management and control of the UPS via direct network connection is provided by an optional SNMPWEBCARD installed in the accessory expansion slot. The additional ENVIROSENSE accessory, when used in conjunction with the SNMPWEBCARD, reports temperature, humidity and status of up to two directly connected contact closure sensors. The HID-compliant USB interface enables full integration with the built-in power management and auto shutdown features of Windows and Mac OS X. Simultaneous and detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces is supported.
Additional features include: PowerAlert monitoring software with USB and serial cables, Emergency Power Off (EPO) interface, integrated 3-bank programmable PDU switching that supports load shedding and remote-reboot of up to (3) individual connected devices and 3-stage metered current monitoring and battery charge status LEDs.
The internal batteries and external battery packs are field-replaceable and hot-swappable.
|
Connectivity
|
|
|
Communication Interface
|
Serial (RS-232)
|
|
Communication Interface
|
USB
|
|
Connector
|
Power NEMA 5-20 (F)
|
|
Connector
|
Power NEMA L5-30 (F)
|
|
Connector
|
Power NEMA L5-30 (M)
|
|
Connector
|
Hardwired
|
|
# Ports
|
9
|
|
General
|
|
|
Form Factor
|
4U Rackmount
|
|
Attributes
|
Line interactive
|
|
Power
|
|
|
Battery Run Time (max)
|
7.5 minute(s)
|
|
Power Provided
|
3000 VA
|
|
Power Provided
|
3600 VA
|
|
Surge Suppression
|
Standard
|
|
Actual Weight
|
102.00 lb(s)
|
|
Compatibility Notes
|
LEDS ALARMS & SWITCHES
Front panel: (5) front panel LEDs - Green POWER LED, Green VOLTAGE CORRECTION LED, 3 color BATTERY CHARGE LED, 3 color OUTPUT LOAD LEVEL LED, red BATTERY WARNING LED. Alarms: 3-function audible alarm indicates power failure conditions (4 short beeps every 10 seconds), overload (continuous short beeps) and low battery (continuous tone) Switches: (2) front panel mounted push-button switches for system enable, self-test and alarm cancel functions. Back panel includes battery charge level switch for internal or external battery configurations
SURGE / NOISE SUPPRESSION
AC surge suppression: 570 joules AC suppression response time: Instantaneous EMI / RFI AC noise suppression: Yes
|
|
Contents
|
UPS, 2-post rackmount kit, software with USB and serial cabling, documentation
|
|
Physical Dimensions
|
13.2"h x 23.6"w x 22.8"d
|
|
Ports/Connectors
|
Outlet quantity / type: (1) L5-30R, (8) 5-15/20R outlets Customized load management receptacles: (3) individually controllable single outlet 5-15/20R load banks Input connection type: L5-30P (hardwiring the input line cord supported) Input cord length: 10 ft.
|
|
Power Notes
|
Voltage compatibility: 120 volts Frequency compatibility: 60Hz
OUTPUT
Output VA: 3000VA with L5-30P input line cord / 3600VA hardwired Output watts: 2880 watts with L5-30P input line cord / 3600 watts hardwired Output nominal voltage: 120V Output voltage regulation: Automatic Voltage Regulation (AVR) circuits maintain clean, regulated computer-grade 120V nominal output, without using battery power, during brownouts to 83V and overvoltages to 145V Output frequency regulation: LINE MODE: Passes line frequency of 60Hz +/-10% Overload protection: Via 40A input circuit breaker
INPUT
Maximum input amps: 24A with L5-30P input / 30A hardwired Recommended electrical service: 120V 30A
BATTERY
Full load runtime: With L5-30P plug - 7.5 minutes (2880 watts) / With hardwired line cord - 5 minutes (3600 watts) Half load runtime: With L5-30P plug - 19 minutes (1440 watts) / With hardwired line cord - 13 minutes (1800 watts) DC system voltage: 48VDC Replacement Battery Cartridge: RBC54 (qty 2)
VOLTAGE REGULATION
Voltage regulation description: Automatic Voltage Regulation (AVR) circuits maintain clean, regulated computer-grade 120V nominal output, without using battery power, during brownouts to 83V and overvoltages to 145V Overvoltage correction: Input voltages between 127 and 145V AC are reduced by 12% Brownout correction: Input voltages between 96 and 108V AC are boosted by 12% Severe brownout correction: 120V only: Input voltages between 83 and 95 are boosted by 24%
|
|
Returns Policy
|
This product is subject to our return policy. Please see our complete return policy for details.
|
|
Warranty - Labor
|
2 Years
|
|
Warranty - Parts
|
2 Years
|
|
Warranty Details
|
2-year warranty, 3 year with registration. Note: registration is required for 3-year warranty. Connected Equipment Insurance (U.S., Canada & Puerto Rico) $250, 000 Ultimate Lifetime Insurance
|