          Tripp Lite PDU 3-Phase Monitored ATS 8.6kW 208V 1U RM (2) L21-30P, 6ft Cords

          More From: Tripp Lite
          Item #: 28184518
          Mfr. Part#: PDU330AT6L21
          Availability: Temporarily Out-of-Stock
          Est. Ship: Call for next available delivery

            Ordering Information

            Price:
            $1,659.67
             
            Tripp Lite Monitored ATS / Auto Transfer Switch provides a redundant power option for network devices powered by a single input connection. Dual PDU input cords support connection to separate PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input connection. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Monitored PDU features include built-in network interface able to communicate power status, load level and other vital information regarding input power and PDU status. Super-fast switchover between primary and secondary power sources occurs in milliseconds. ATS functionality is supported by any two compatible AC power sources regardless of phase angle, to support a variety of advanced redundant power networking applications. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Digital load meter and status LEDs display output current and primary or secondary power availability.
            Collapse & Return to Top
            Actual Weight 26.80 lb(s)
            Compatibility Notes Features

            208V 8.6kW Three Phase Automatic Transfer Switch (ATS) / Monitored PDU with built-in web/network interface
            Provides a redundant power option for critical networking equipment with a single input power connection
            Digital display reports output power consumption in amps for each output phase
            ATS switching module is in 1U horizontal rackmount form factor
            Requires separate purchase 0U vertical PDU accessory PDU3VD351 (51 C13 outlets), PDU3V20D354 (54 C13 outlets), PDU3V20D354A (42 C13 and 12 C19 outlets) or PDU3V20D354B (48 C13 and 6 C19 outlets)
            Set of two 6 foot / 1.8m NEMA L21-30P inputs support connection to separate A & B power sources
            ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable
            ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system
            Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported
            On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source
            Super-fast switchover between primary and secondary power sources occurs in 2-5 milliseconds
            Built-in SNMP/ethernet interface reports voltage, frequency and PDU loading per-phase via network or secure web browser interface with options for user specified alarm and notification thresholds
            Supports in-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors
            DHCP/Manual configuration support
            10/100 Mbps auto-sensing allows optimal communication with 10/100 Base-T networks
            Real-time clock backup maintains the time of day and date even if the PDU is not powered on
            Tiered access privileges allow an administrator and a guest to login via web browser for monitoring
            Alert notifications via email or SNMP traps offer immediate event notification
            Firmware upgrade ability supports future product enhancements
            Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols
            Fully compatible with FREE PowerAlert Network Management System / NMS Software
            Connectivity
            # Ports 0
            Connector Power NEMA L21-30 (M)
            Contents Unit, documentation
            General
            Color Black
            Form Factor 1U Rackmount
            Physical Dimensions 1.7"h x 16.9"w x 26"d
            Ports/Connectors Output Receptacles: C13, C19
            Output Receptacle Details: 0U vertical output power distribution component is a required accessory; Order REQUIRED PDU accessory PDU3V351 (51 C13 outlets), PDU3V354 (48 C13 and 6 C19 outlets) or PDU3V354A (42 C13 and 12 C19 outlets) or PDU3V20D354B (48 C13 and 6 C19 outlets)
            PDU Input Plug Type: NEMA L21-30P
            Input Cord Details: Includes two 6ft/3m input cords
            Power
            Power Provided 208 V
            Power Notes Output

            Output Capacity Details: 8.6kW total; 13.9A per bank (balanced)
            Frequency Compatibility: 50/60Hz
            Output Nominal Voltage: 208V single phase output
            Overload Protection: (3) 20A double-pole breakers (1 per output phase
            Individual Outlet Switching: No

            Input

            PDU Input Voltage: 208V
            Maximum Input Current: 24A
            Input Phase: 3-Phase
            Returns Policy This product is subject to our return policy. Please see our complete return policy for details.
            Standards
            Compliant Standards CSA, NOM, RoHS, UL
            UNSPSC 39121017
            Warranty - Labor 2 Years
            Warranty - Parts 2 Years