MacConnection Clearance Center. Shop Now!

MacConnection Interactive eCatalog


          Tripp Lite SmartOnline 1kVA 120V Online Double Conversion Tower UPS Interactive LCD (6) NEMA 5-15R Outlets

          More From: Tripp Lite
          Item #: 15694607
          Mfr. Part#: SU1000XLCD
          Availability: Temporarily Out-of-Stock
          Est. Ship: Call for next available delivery

          • Provides 1000VA, 900watt(s), 120V power
          • Surge Suppression is Standard
          • Connector(s): Power NEMA 5-15 (M), Power NEMA 5-15 (F)
          • 6 Outlets
          • 4.8 minute(s) Battery Runtime at Full Load
          • Attributes include Double conversion online, RJ-11 line protection, Automatic voltage regulation (AVR)

          Ordering Information

          Tripp Lite Smart Online UPS systems offer high performance power protection ideal for critical server and network equipment in a variety of application environments. Online, double-conversion Uninterruptible Power Supply / UPS maintains perfectly regulated output power by continuously converting raw AC input to DC, then re-converting output back to AC. Sine wave AC output with +/-2% voltage regulation powers network equipment continuously, even during severe brownouts and overvoltages, all without depleting UPS battery reserves. Maintains battery-derived AC output during power failures with zero transfer time. Extended runtime options available. Interactive LCD interface reports UPS operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options. Highly efficient operation in optional economy mode saves BTU heat output and energy costs. Network management interfaces support communications via USB, RS-232, contact-closure and optional SNMPWEBCARD network interface. Built-in DB9 port offers both enhanced RS-232 data and basic contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. LED display reports UPS operating mode, line power availability, battery mode operation, inverter operation, ECO mode status and output power availability. Audible alarm with push-button momentary alarm-cancel and silent-mode LCD configuration options. Programmable self-test. Fault-tolerant auto-bypass mode. Battery independent restart. Field-replaceable, hot-swappable internal batteries and external battery packs.
          Collapse & Return to Top
          Compatibility Notes Key Features

          Tripp Lite SU1000XLCD 1000VA/1kVA/900W online, double conversion tower UPS
          Selectable 100/110/120/127V output (120V factory preset)
          NEMA 5-15P input, (6) NEMA 5-15R outlets
          Two switched outlets support remote reboot and programmable load shedding options
          Supports 2% output voltage regulation and zero transfer time in double conversion mode
          Economy mode option offers enhanced efficiency, reduced power consumption and lower BTU emissions
          15 minutes runtime at 50% load (450W) and 4.8 minutes at 100% load (900W) with internal batteries
          Extended runtime options available with BP24V15RT2U (limit 1), BP24V28-2U (limit 1) or BP24V70-3U (no limit) external battery packs (external battery configurations require Tripp Lite's External Battery Configuration Software)
          LCD interface reports operating mode plus 10 selectable screens of UPS data (Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Load kVA, Load kW, Battery charge percentage, Battery voltage and Minutes runtime)
          LCD interface also supports (9) screens of advanced UPS configuration, setup and information options (Output voltage, Output frequency, Frequency regulation, Bypass range, Economy mode, Audible alarm, Overload alarm, External battery, Display IP address)
          Single line TEL / Network surge suppression
          Electronic bypass maintains utility output during a variety of UPS fault conditions
          Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement
          Frequency regulation / conversion mode offers generator-compatible frequency correction or conversion of frequency from 50 to 60Hz or 60 to 50Hz
          Built-in USB, RS-232, contact-closure and optional SNMPWEBCARD accessory monitoring options
          HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
          Included PowerAlert UPS monitoring software


          Front panel display: Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options
          Alarms: Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
          Alarm cancel operation: Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
          Switches: (2) switches control off/on power status and alarm-cancel/self-test operation


          UPS AC suppression rating: 570 Joules
          UPS AC suppression response time: Instantaneous
          UPS Dataline suppression: (1) line TEL/DSL (1 in / 1 out); 10/100BaseT Ethernet
          EMI/RFI AC noise suppression: Yes


          Cold Start (startup in battery mode during a power failure): Cold-start operation supported
          High availability UPS features: Automatic inverter bypass; Hot swappable batteries
          Green & high efficiency features: High efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy mode operation


          UPS Certifications: Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI)
          # Ports 6
          Communication Interface Serial (RS-232), USB
          Connector Power NEMA 5-15 (F), Power NEMA 5-15 (M)
          Contents UPS, software, cabling, documentation
          Attributes Automatic voltage regulation (AVR), Double conversion online, RJ-11 line protection
          Color Black
          Form Factor Tower
          Physical Dimensions 10"h x 6.8"w x 13.2"d
          Ports/Connectors Built-in UPS output receptacles: (6) 5-15R outlets
          Built-in controllable switched load banks: (2) switchable single-outlet 5-15R load banks
          UPS input connection type: 5-15P
          Input circuit breaker: 15A
          UPS Input cord length: 10ft (3m)


          Communications interface USB (HID enabled); DB-9 Serial; Contact closure; EPO (emergency power off); Slot for OPTIOANL SNMP/Web interface card
          Network monitoring port description: Supports detailed monitoring of UPS and site power conditions; DB-9 port supports RS-232 and contact closure communications
          PowerAlert software: Included
          Communications cables: USB and DB-9 cabling included
          WatchDog compatibility: Supports Watchdog application, O/S and hard-reboot restart options for remote applications
          Battery Run Time (max) 4.8 minute(s)
          Power Provided 1000 VA, 120 V, 900 watt(s)
          Surge Suppression Standard
          Power Notes OUTPUT

          Output Capacity: 1000VA/900W
          Output Capacity Details: ON LINE MODE: Maximum output capacity ratings are reduced for some nominal voltage settings (127/120/115/110V 900 watts, 100V 810 watts). FREQUENCY REGULATION / CONVERSION MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120/115/110V 630 watts / 100V 567 watts).
          Crest Factor: 3 to 1
          Nominal Output Voltages Supported: 100V; 110V; 120V; 127V
          Nominal Voltage details: 120V default
          Frequency compatibility: 50/60Hz; Supports 50 to 60Hz and 60 to 50Hz conversion
          Frequency compatibility details ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency when input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal.
          Output voltage regulation (line mode): +/- 2%
          Output voltage regulation (Economy line mode): +/- 10%
          Output voltage regulation (Battery mode): +/- 3%
          Output AC waveform (AC mode): Pure Sine wave
          Output AC waveform (battery mode): Pure Sine wave


          Rated input current (at maximum load): 10A
          Nominal Input Voltages Supported: 100VAC; 110VAC; 120VAC; 127VAC
          Nominal input voltage description: 120V factory default
          Recommended Electrical Service: 15A, 120V


          Full load runtime: 4.8 minutes (900W)
          Half load runtime: 15 minutes (450W)
          Expandable battery runtime: Extended runtime supported via OPTIONAL external battery packs
          External battery pack compatibility: BP24V15RT2U (limit 1); BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible)
          Expandable runtime description: External battery configurations require the use of Tripp Lite's External Battery Configuration Software
          DC system voltage: 24VDC
          Battery recharge rate (included batteries): Less than 3 hours from 10% to 90%
          Replacement battery cartridge (internal UPS battery replacement): RBC24V-LCD
          Battery Access: Battery access door
          Battery replacement description: Hot-swappable, user replaceable batteries


          Voltage regulation description: Online, double conversion power conditioning
          Overvoltage correction: 2% output voltage regulation during overvoltages to 150V
          Undervoltage correction: 2% output voltage regulation during undervoltages to 55V (33% load), 70V (70% load), 100V (100% load)
          Returns Policy This product is subject to our return policy. Please see our complete return policy for details.
          Compliant Standards CSA, FCC Part 15 B, NOM, UL
          UNSPSC 39121011
          Warranty - Labor 2 Years
          Warranty - Parts 2 Years
          Warranty Details Connected Equipment Insurance (U.S., Canada & Puerto Rico): $250,000
          Collapse & Return to Top
          Add this product to your cart with selected accessories
          Add To Cart
          Battery Backup Accessories (2 Products)
          Controller Cards (1 Product)
          Environmental Monitoring (1 Product)
          Other Batteries (3 Products)
          Power Cords (7 Products)
          Power Distribution (6 Products)
          Power Distribution Units (6 Products)
          Rack Mount Accessories (1 Product)
          Add this product to your cart with selected accessories
          Add To Cart
          Collapse & Return to Top
          Description Availability Unit Price  
          View All Warranties
          Collapse & Return to Top