          Est. Ship: Call for next available delivery

          • Provides 40000VA, 32000watt(s) power
          • Surge Suppression is Standard
          • Connector(s): Hardwired
          • 1 Outlets
          • 13 minute(s) Battery Runtime at Full Load
          • Attributes include Double conversion online

          Ordering Information

          Price:
          $17,635.57
           
          Tripp Lite's SU40KX (40kVA) SmartOnline Modular 3-Phase Intelligent, True On-Line UPS System provides 100% system availability with N+1 modular architecture and 1+1 parallel capability. In N+1 configuration, the SU40KX provides two self-contained, redundant 20kVA power modules that can be hot-swapped (load remaining powered) if maintenance is required. In 1+1 configuration, two SU40KX models connected in parallel can provide fail-safe redundancy (two 40kVA models supporting a 40kVA load) or increased capacity (two 40kVA models supporting an 80kVA load). Large capacity 40,000VA/32,000W UPS continually converts incoming AC power into filtered DC power and then resynthesizes it back into AC power with a pure sine wave. Perfectly regulated, continuous sine wave output with zero transfer time assures compatibility with all equipment types.

          High input power factor, advanced IGBT inverter technology and Digital Signal Processor (DSP) technology produce less than 3% input total harmonic distortion (THDi). With low THDi, generators run cooler and last longer, allowing managers to save installation costs by installing a generator with a capacity equal to the equipment load (1:1 ratio). Extremely efficient operation (up to 97%) saves money by lowering electricity consumption. Hardwire input and output connections support a variety of permanent or PDU-style power connections. Frequency is 50 or 60 Hz (auto-selectable). The SU40KX combines internal power and battery modules in a single small-footprint tower compartment.

          Typical half-load/full-load runtimes are 13 min./5.5 min. Battery runtime can be extended with optional stand-alone hardwired external battery modules (Models BP480V26B and BP480V40C, available separately). A manual bypass breaker and an automatic bypass function ensure 100% availability of connected equipment by safely passing through AC power if the UPS requires maintenance.
          Collapse & Return to Top
          Actual Weight 908.00 lb(s)
          Compatibility Notes Key Features

          N+1 configuration: If maintenance is required, two self-contained, redundant 20kVA power modules can be hot-swapped with the load remaining powered
          1+1 configuration: Two SU40KX can be connected in parallel to provide either fail-safe redundancy or increased capacity
          High input power factor, advanced IGBT inverter technology and Digital Signal Processor (DSP) technology produce low input total harmonic distortion (THDi)
          Low THDi (less than 3%) reduces installation costs by allowing 1:1 generator sizing
          Extremely efficient operation (up to 97%) saves money by reducing electricity consumption
          True on-line, double-conversion UPS with IGBT technology provides pure sine wave AC output at all times
          Maintains continuous operation with zero transfer time through blackouts, voltage fluctuations and surges
          Removes harmonic distortion, electrical impulses, frequency variations and other hard-to-solve power problems
          40,000VA/32,000W power capacity with 3-phase, hardwire input/output connections
          Wide input voltage correction range: 173-300V/276-477V AC
          Internal power and battery modules are combined in a single small-footprint tower compartment. Typical half-load/full-load runtimes are 13 min./5.5 min. Battery runtime can be extended with optional stand-alone hardwired external battery modules (Models BP480V26B and BP480V40C, available separately)
          Front panel combination LCD/LED display includes a real-time event log screen with up to 500 events listed
          Dynamic battery management screen optimizes battery function to lengthen service life and allow cold restart of the UPS
          Built-in RS-232 communication port works with included PowerAlert Software to provide shutdown commands and reporting on a single server
          Accessory slot accepts an optional internal SNMP card (Model SNMPWEBCARD) for remote shutdowns, reboots and more
          Emergency Power Off button turns UPS output OFF and disables Bypass output
          Built-in Emergency Power Off (EPO) dry-contact interface supports remote emergency shutdown in large facilities

          LEDS ALARMS & SWITCHES

          LED Indicators 4-LED Display: Displays normal AC input, on battery power, bypass input and fault conditions
          Alarms Alarms signal a variety of operational conditions: low-battery, overload, shutdown, bypass and more
          Alarm cancel operation: Power-fail alarm can be silenced using alarm-cancel switch
          Switches: ON button turns UPS inverter on. OFF button turns UPS inverter off. LCD Display Control Buttons browse through and select items displayed on LCD screen. EPO (Emergency Power Off) button turns UPS output off and disables Bypass output

          SPECIAL FEATURES

          Cold Start (startup in battery mode during a power failure): Cold-start operation supported
          High availability UPS features: Automatic inverter bypass; Hot swappable batteries
          Green & high efficiency features: High efficiency economy mode operation; Schedulable daily hours of economy mode operation
          Connectivity
          # Ports 1
          Communication Interface Serial (RS-232)
          Connector Hardwired
          Contents UPS, cabling, software, documentation
          General
          Attributes Double conversion online
          Color Black
          Form Factor Tower
          Physical Dimensions 45.8"h x 20.5"w x 33.7"d
          Power
          Battery Run Time (max) 13 minute(s)
          Power Provided 32000 watt(s), 40000 VA
          Surge Suppression Standard
          Power Notes OUTPUT

          Output Capacity: 40,000VA/32,000W
          Output power factor: 0.8
          Crest Factor: 3:1
          Nominal Output Voltages Supported: 220/380V, 230/400V, 240/415V, 3-phase Wye
          Frequency compatibility: 50/60Hz
          Output voltage regulation (line mode): +/- 2%
          Output voltage regulation (Battery mode): +/- 2%
          Output AC waveform (AC mode): Sine wave
          Output AC waveform (battery mode): Pure Sine wave

          INPUT

          Rated input current (at maximum load): 48A/50A/53A
          Nominal Input Voltages Supported: 220/380, 230/400, 240/415VAC 3-phase Wye
          UPS input connection description 220/380V, 230/400V or 240/415V , 3-phase, 4-wire + ground, wye

          BATTERY

          Full load runtime: 5.5 minutes (32kW)
          Half load runtime: 13 minutes (16kW)
          Expandable battery runtime: Supports extended runtime with optional external battery packs
          External battery pack compatibility: BP480V26B, BP480V40C, BP480V55, BP480V78, BP480V103, BP480V140
          Expandable runtime description External battery pack wiring is contractor supplied
          DC system voltage: +/- 240VDC
          Battery recharge rate (included batteries): 4 hours from 10% to 90%
          Battery replacement description: Hot-swappable, replaceable batteries

          VOLTAGE REGULATION

          Voltage regulation description: Online, double-conversion power conditioning
          Overvoltage correction: Maintains continuous operation without using battery power during overvoltages to 276-477 (3-phase, 4-wire, wye), reducing output within 1% of nominal
          Undervoltage correction: Maintains continuous operation without using battery power during brownout/undervoltage conditions to 173-300 (3-phase, 4-wire, wye)

          SURGE / NOISE SUPPRESSION

          UPS AC suppression rating: 5950 Joules
          UPS AC suppression response time: Instantaneous
          EMI / RFI AC noise suppression: Yes

          LINE / BATTERY TRANSFER

          Transfer time: No transfer time (0 ms.) in online, double-conversion mode
          Low voltage transfer to battery power (setpoint): Maintains continuous operation without using battery power during brownout/undervoltage conditions to 173-300V AC (3-phase, 4-wire, wye). Below this point, output is maintained utilizing reserve battery power
          High voltage transfer to battery power (setpoint): Maintains continuous operation without using battery power during overvoltages to 276-477V AC (3-phase, 4-wire, wye), reducing output within 1% of nominal. Above this point, output is maintained utilizing reserve battery power
          Returns Policy This product is subject to our return policy. Please see our complete return policy for details.
          Standards
          Compliant Standards RoHS
          UNSPSC 39121011
          Warranty - Labor 2 Years
          Warranty - Parts 2 Years
          Collapse & Return to Top
          Add this product to your cart with selected accessories
          Add To Cart
          Battery Backup Accessories (1 Product)
          Environmental Monitoring (1 Product)
          Other Batteries (2 Products)
          Add this product to your cart with selected accessories
          Add To Cart
          Collapse & Return to Top

          Our Accessibility Policy


          We endeavor to make our website accessible to any and all users. Please contact us toll-free at 800-998-4388 if you need assistance with navigating our blog, website, or placing an order. We appreciate your business and are happy to answer any questions that you may have.
          09