          • Provides 10000VA, 8000watt(s), 230V power
          • Surge Suppression is Standard
          • Connector(s): Power IEC 320 EN 60320 C19 (F), Hardwired
          • 6 Outlets
          • 4 minute(s) Battery Runtime at Full Load
          • Attributes include Double conversion online

          Ordering Information

          Price:
          $4,555.00
           
          This is a Trip Lite Global 8,000VA (8kVA) on-line, double-conversion UPS system for critical server, network and telecommunications equipment. It installs in 6 rack spaces (3U power module and 3U battery pack) with a maximum installed rack depth of 32.5". Battery runtime is expandable with optional BP240V10RT3U external battery packs. The UPS actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output, operating continuously without consuming battery power during brownouts to 156V and overvoltages to 276V.

          The detachable input-output PDU module with a manual bypass switch enables hot-swap UPS replacement without disrupting power to connected equipment. The network management interfaces support communications via RS-232, contact-closure port and an accessory expansion slot for the optional SNMPWEBCARD. Detailed monitoring of equipment load levels, self-test data and utility power conditions via network interfaces is supported. PowerAlert monitoring software with complete cabling and an Emergency Power Off (EPO) interface are also provided. The front panel LEDs give you at-a-glance confirmation of line power status, battery power status, AC-to-DC conversion, DC-to-AC conversion, bypass mode and output power status. The LED/LCD display panel rotates for better viewing in either rackmount or tower configuration and the LCD panel with scroll buttons provides detailed diagnostic test information at startup and during self tests, plus real-time data on input and output voltage, frequency (Hz), load percentage and battery charge level.
          Collapse & Return to Top
          Actual Weight 191.50 lb(s)
          Compatibility Notes LEDS ALARMS & SWITCHES

          Front panel: 6-LED display - line power, bypass, inverter, charger, output AC and battery operation. LED/LCD display panel easily rotates for better viewing in rackmount or tower configuration
          Alarms: multi-function audible alarm offers notification of UPS start, backup operation, low battery, overload, UPS fault, inverter fault, DC bus fault, overtemperature, remote shutdown, shutdown imminent and shutdown complete
          Switches: main power off/on switch, plus 2 switches to set and execute scrollable LCD
          functions

          SURGE / NOISE SUPPRESSION

          AC suppression response time: Instantaneous
          EMI / RFI AC noise suppression: Yes

          COMMUNICATIONS

          Network monitoring port: (2) built-in DB-9 monitoring ports (1-RS232 / 1-contact closure), software and cabling included. Includes PowerAlert UPS monitoring software for all common network and standalone operating systems. Cabling included.
          SNMP compatibility: Built-in accessory slot accommodates internal SNMP / Web card and other network accessories (available separately).
          WatchDog compatibility: compatible with Tripp Lite's Watchdog system service to restore operation to locked equipment through soft reboot of application / OS or hard power off/on reboot of connected equipment -- ideal for unattended kiosk applications

          LINE / BATTERY TRANSFER

          Transfer time from line power to battery mode: Zero, online UPS continuously converts incoming AC to DC, then back to AC. When line power is interrupted, UPS maintains continuous output from battery reserves with absolutely no disruption in output AC power.
          Low voltage transfer to battery power: Maintains continuous operation during undervoltages as low as 156VAC. Below this point, output is maintained utilizing battery reserves.
          High voltage transfer to battery power Maintains continuous operation during overvoltages to 276V AC. Above this point, output is maintained utilizing battery reserves.
          Connectivity
          # Ports 6
          Communication Interface Contact closure, Serial (RS-232)
          Connector Hardwired, Power IEC 320 EN 60320 C19 (F)
          Contents UPS, external battery pack, (2) sets rackmount rails, tower stands, software, cabling, documentation
          General
          Attributes Double conversion online
          Color Black
          Form Factor 6U Rackmount, Tower
          Physical Dimensions 10.3"h x 17.5"w x 32.5"d
          Ports/Connectors Outlet quantity / type: (6) individually breakered C19 outlets
          Input connection type: Hardwired
          Power
          Battery Run Time (max) 4 minute(s)
          Power Provided 10000 VA, 230 V, 8000 watt(s)
          Surge Suppression Standard
          Power Notes Voltage compatibility: 208VAC (200/208/220/230/240V)
          Frequency compatibility: 50/60Hz

          OUTPUT

          Output: 8000W/10000VA
          Output nominal voltage: 208VAC (200/208/220/230/240V)
          Output voltage regulation: maintains pure sine wave output at all times, regulated within 2% of selected nominal output voltage, less than 3% total harmonic distortion when used with computer loads
          Output frequency regulation: regulates line frequency to 50/60Hz +/- 0.05Hz

          INPUT

          Maximum input current: 200V 46.7A, 208V 44.9A, 220V 42.4A, 230V 40.6A, 240V 38.9A

          BATTERY

          Full load runtime: 4 minutes (10,000VA/8000W)
          Half load runtime: 10 minutes (5000VA/4000W)
          Expandable battery runtime: Runtime is expandable with optional BP240V10RT3U external battery packs; connects to UPS via included 3-wire DC cable
          DC system voltage: 240VDC
          Typical battery lifespan: 4-6 years
          Battery recharge rate: less than 8 hours to 90% (included battery set only)

          VOLTAGE REGULATION

          Description: double-conversion online topology gives this UPS the ability to maintain output voltage within +/-2% of selected nominal voltage at all times
          Overvoltage correction: maintains continuous operation without using battery power during overvoltages to 276V AC, regulating output within 2% of selected nominal
          Brownout correction: maintains continuous operation without using battery power during brownout / undervoltage conditions to 156V AC, regulating output within 2% of selected nominal
          Returns Policy This product is subject to our return policy. Please see our complete return policy for details.
          UNSPSC 39121011
          Warranty - Labor 2 Years
          Warranty - Parts 2 Years
          Warranty Details $250,000 Connected equipment insurance (USA, Puerto Rico & Canada only)
          Collapse & Return to Top
          Add this product to your cart with selected accessories
          Add To Cart
          Battery Backup Accessories (1 Product)
          Environmental Monitoring (1 Product)
          Power Distribution (3 Products)
          Power Distribution Units (3 Products)
          Rack Mount Accessories (2 Products)
          Add this product to your cart with selected accessories
          Add To Cart
          Collapse & Return to Top

          07